PZEM 004T 4.0 Single Phase Wattmeter Kwh Meter TTL Modbus-RTU 220V 32A/63A/100A Electricity Volt Amp Frequency Energy Meter
You will be redirected to AliExpress to complete your purchase
Specifications
- Brand Name
- peacefair
- High-concerned chemical
- None
- Origin
- Mainland China
- DIY Supplies
- Electrical
- Battery Included
- No
- Measuring Energy Range
- 100A/22000W
- Display Type
- Digital Only
- Output Voltage
- 220V
- Model Number
- PZEM-004T
- Certification
- CE, FCC
- Power Supply
- AC
- Phase
- single phase
- Rated Voltage
- 220V
- Dimensions
- 7.8cm*3.7cm
- Operating Temperature
- -10-60degree
- Accuracy Class
- 1.0
- Max Operating Current
- 100A - 119A
- Certificate
- CE,FCC
- Accessory
- coil CT/split CT
- Communicate Port
- TTL
- Current range
- 32A/63A/100A
- Voltage range
- 80-260V
- Power range
- 0-22kw
- Power factor
- 0-1
- Frequency
- 45-65Hz
- Protocol
- Modbus
- Choice
- yes
- semi_Choice
- yes
Product Description
PZEM 004T 4.0 Version Single Phase Power Meter Kwh Meter TTL Modbus-RTU 220V 100A Electricity Volt Amp Frequency Energy Meter
We provide the software to connect it with the PC. If you want to connect it with other terminal device such as PLC,SCM and so on, please prepare the fitable cable and write the program by yourself.
This document describes the specification of the PZEM-004T AC communication module, the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module is without display function, the data is read through the TTL interface.
PZEM-004T-10A: Measuring Range 10A (Built-in Shunt)
PZEM-004T-100A: Measuring Range 100A (external transformer)
Software downloads: //pan.baidu.com/s/1cscXu-ReePyi6b5UurI9Iw?pwd=dp6y
Extraction code: dp6y
1. Working voltage: 80 ~ 260VAC
2. Test voltage: 80 ~ 260VAC
3. Rated power: 100A/22000W
4. Operating frequency: 45-65Hz
5. Measurement accuracy: 1.0 grade
Function
Voltage
1.1.1 Measuring range:80~260V
1.1.2 Resolution: 0.1V
1.1.3 Measurement accuracy: 0.5%
1.2 Current
1.2.1 Measuring range: 0~10A(PZEM-004T-10A); 0~100A(PZEM-004T-100A)
1.2.2 Starting measure current: 0.01A(PZEM-004T-10A); 0.02A(PZEM-004T-100A)
1.2.3 Resolution: 0.001A
1.2.4 Measurement accuracy: 0.5%
1.3 Active power
1.3.1 Measuring range: 0~2.3kW(PZEM-004T-10A); 0~23kW(PZEM-004T-100A)
1.3.2 Starting measure power: 0.4W
1.3.3 Resolution: 0.1W
1.3.4 Display format:
<1000W, it display one decimal, such as: 999.9W
≥1000W, it display only integer, such as: 1000W
1.3.5 Measurement accuracy: 0.5%
1.4 Power factor
1.4.1 Measuring range: 0.00~1.00
1.4.2 Resolution: 0.01
1.4.3 Measurement accuracy: 1%
1.5 Frequency
1.5.1 Measuring range: 45Hz~65Hz
1.5.2 Resolution: 0.1Hz
1.5.3 Measurement accuracy: 0.5%
1.6 Active energy
1.6.1 Measuring range: 0~9999.99kWh
1.6.2 Resolution: 1Wh
1.6.3 Measurement accuracy: 0.5%
1.6.4 Display format:
<10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh
≥10kWh, the display unit is kWh, such as: 9999.99kWh
1.6.5 Reset energy: use software to reset.
1.7 Over power alarm
Active power threshold can be set, when the measured active power exceeds the threshold, it can alarm
1.8 Communication interface
RS485 interface
1 Communication protocol
1.1 Physical layer protocol
Physical layer use UART to TTL communication interface
Baud rate is 9600, 8 data bits, 1 stop bit, no parity
1x PZEM-004T ACVoltmeter Ammeter with outcase
1x CT
Product information last updated on December 30, 2025