AliExpress.io
Yieryi-Stylo Testeur de PH Numérique, Testeur Litmus, Haute Précision, Qualité de l'Eau 0.01, Fonction Bandes de Test ATC

Yieryi-Stylo Testeur de PH Numérique, Testeur Litmus, Haute Précision, Qualité de l'Eau 0.01, Fonction Bandes de Test ATC

4.324+ sold
€12.19€15.43
0% OFF
Buy on AliExpress

You will be redirected to AliExpress to complete your purchase

Specifications

Nom de marque
yieryi
Batterie incluse
Non
Origine
CN (Origine)
Produit chimique à haute préoccupation
Aucun
Est-ce un appareil intelligent
Non
Type d'affichage
numérique, numérique
Avec rétroéclairage ou pas
Oui
Numéro de Modèle
PH-2pro
Certification
CE

Product Description

Feature :

Easy to Use: Simply immerse the pH meter electrode in the solution to be tested, readings are quickly display on a large lcd display

Wide Application: Ideal instrument for any aquarium, the fishing industry, swimming pools, spa, school laboratories, food & beverage, drinking water etc.

Auto Calibrated: Features in-built calibration with 2 buffer powders(included).Just press a button to finish the calibration. This pH meter is factory calibrated. Users can use it directly.

Fast and Accurate Results: No need to work with those annoying color charts and test strips.Resolution: 0.01 pH, Accuracy: ±0.01 pH

Compact Portable Design: Pocket fitting pH meter that's also lightweight and compact. Total concealed fit in your bag or pocket for easy, casual carrying.

Item Describe:

1. Display: LCD Digital

2. Accuracy: 0.01

3. Resolution: 0.01

4. Operating Temperature: 0~60°C

5. Measuring Range: 0.00~14.00

6. Probe Type: Precision glass bulb electrode



How To Use :

1. Remove protective cap.

2. First rinse the electrode with distilled water and suck it with filter paper.

3. Turn the meter on by pressing “ON/OFF” key.

4. Immerse the pH meter electrode in the solution to be tested (should not be over the immersion line).

5. Stir gently and wait around 30 seconds till the reading stabilizes.

6. After finishing, clear the electrode with pure water, turn the meter off by pressing “ON/OFF” key.

7. Always replace the protective cap after use.



Steps :

1. Turn on PH meter

2. Disolve each buffer solution in 250ML of distilled water

3. Immerse the electrode into the PH 6.86 solution,(under the temperature of 25)

4. Press the “CAL”(calibration)button for 5 seconds and release

-Display will start flashing 6.86

-Wait until the display stops flashing.

Rinse the electrode with distilled water and dry it with filter paper.

5. Immerse the electrode in PH 4.00 solution,

-Press“CAL”button for 5 seconds,then press and release immediately second time

-Reading will start flashing 4.00

-Wait until display stops flashing

Rinse and dry the electrode with distilled water as before.

6. Place the meter back to the buffer solution to test calibration.If incorrect,please repeat the calibration

7. If approximate PH of your test solution is known to be above 7.0,calibrate the meter using 6.86 and 9.18 solution. To do this,please follow the calibration chart,The third step is the calibration method for 9.18 point.




Package include:

1pc * pH Meter

3pc * Bags Buffer Powder

1pc * Instruction Manual



Kindly Reminder:

1. If the tester was used or lay aside long time: recalibrate it.

2. If you open battery case or replace battery: recalibrate it.

3. The glass bulb of the electrode is fragile. Don't touch it by hard tools and fingers, suck the water on it gently when cleaning.

Reset function: Turn it on,Press the ON/OFF key for 3 seconds , and then release it. When "----" appears on the screen, the reset is successful

what is different with old one?

This is the new ph-02 Meter, which can not only measure pH value, but also synchronize the FUNCTION of PH test paper and measure temperature at the same time. Of course, it continues the function of automatic temperature-repair and automatic calibration of the old model




Pros & Cons

Pros

  • Précision de mesure de 0,01, garantissant des résultats exacts pour l'analyse de l'eau
  • Écran LCD rétroéclairé pour une lecture aisée, même dans des environnements peu éclairés
  • Large champ d'application, adapté à de nombreux usages quotidiens et professionnels
  • Fonction ATC (compensation de température) incluse pour des mesures précises quelle que soit la température du liquide

Cons

  • La batterie n'est pas fournie avec le produit, il faut la commander séparément
  • Aucune information sur les dimensions exactes du stylo testeur n'est disponible dans la fiche produit
  • Le produit n'est pas un appareil intelligent, il ne prend pas en charge la connexion à des dispositifs connectés
  • La description du produit est incomplète, la fin du texte est coupée

Common Questions

La batterie est-elle incluse avec ce stylo testeur de pH ?

Non, la batterie n'est pas fournie avec le produit selon les spécifications techniques fournies.

Sur quels types de liquides peut-on utiliser ce testeur de pH ?

Ce testeur peut être utilisé pour analyser l'eau d'aquarium, les piscines, les spas, les eaux potables, les boissons, dans les laboratoires scolaires et l'industrie de la pêche.

Quel est le matériau de la sonde de ce testeur numérique de pH ?

La sonde est en verre spécialisé, conçue pour assurer une précision de mesure de 0,01 et une durabilité lors des tests dans divers liquides.

Comment utiliser ce stylo testeur de pH ?

Il suffit d'immerger l'électrode du testeur dans le liquide à analyser, la mesure s'affiche rapidement sur l'écran LCD rétroéclairé pour une lecture facile et immédiate.

Ce testeur de pH possède-t-il une certification de conformité ?

Oui, ce produit est certifié CE selon les spécifications fournies.